Profile Mini

Good design is not what is added, but what can be removed.

A continuation of the minimalist architectural aesthetic of the original Profile series maintaining the same technical performance, energy efficiency and exceptional illumination.

  • Precisely controlled optimal distributions.
  • No direct or indirect view of the light source.
  • Low operating temperatures, quality parts and construction.
  • Strategic LED selection, binning and board design.
  • Available in 3000K, 3500K or 4000K with SDCM < 2 and CRI > 80.
  • Third party tested and backed by a 5-year warranty.

WELL Building v2 + LEED v4 Compliance Reference Guide

A reference guide to assist in selecting Profile Mini and other Fluxwerx luminaires that comply with WELL Building v2 and LEED v4 requirements.

get the guide

Optics

The convergence of Anidolic optics with an open aesthetic and architectural materials creates the opportunity for a broad range of applications. Vertical optical structures with linear light extraction elements deliver optical precision and control, balancing occupant comfort with high performance and value.

  • Low Angle Indirect
  • Anidolic Optical Structures
  • Linear Extraction

Low Angle Indirect

Low angle indirect distributions require minimal suspension distances to create uniform, luminous ceiling planes.

Suspended luminaires with combined direct and indirect distributions maximize visual comfort as well as the spatial and energy efficiency of the architectural volume.

Anidolic Optical Structures

Anidolic optical structures disperse and mix light, eliminating any visible images of the LED point source and ensuring accurate and consistent color.

Linear Extraction

Linear extraction elements in the lens precisely refract and reflect light directly and indirectly, emitting high performance distributions with exceptional optical control and efficacies. The clarity of the lens and open designs of the luminaries uniquely creates visibility directly through the fixture and allows natural light to flow through and permeate the space.
1 / 3

Best Practices

spaceenvironmentproductqtydrop + spacinguniformitylight + energy
Open Office60 x 64 x 965 Up l 35 Dn / 22W4 runs of 60'18" l 15' o.c.
2.1 (Desk)
5.6 (Ceiling)
39 fc l 0.34 W/ft²
Open Office60 x 64 x 965 Up l 35 Dn / 18W5 runs of 60'18" l 12 o.c.1.6 l 3.239 fc l 0.34 W/ft²
Open Ceiling Office60 x 64 x 1220 Up l 80 Dn / 28W30 runs of 8'36" l 10'x12'1.4 l 1.543 fc l 0.44 W/ft²
Meeting Room18 x 12 x 965 Up l 35 Dn / 28W2 runs of 8'18" l 9' o.c.1.6 l 4.937 fc l 0.51 W/ft²
Private Office12 x 9 x 9
65 Up l 35 Dn / 36W1 run of 8'18" l N/A1.6 l 3.642 fc / 0.65 W/ft²
Classroom30 x 36 x 940 Up l 60 Dn / 22W3 runs of 28'18" l 12' o.c.1.9 l 3.845 fc l 0.43 W/ft²
Classroom30 x 36 x 940 Up | 60 Dn / 18W3 runs of 32'18" l 10' o.c.1.7 l 2.941 fc l 0.38 W/ft²
Top