Loop Suspended

Design is the continuous pursuit of perfection

Endcaps + Dimensions

Fixtures are available in 4′, 6′ and 8′ nominal sections that can be ganged together to create continuous runs.

[F] Flat

[R] Radius

Finishes

[W] WHITE POWDERCOAT
[A] CLEAR ANODIZED
[S] METALLIC SILVER POWDERCOAT
[B] BLACK POWDERCOAT

Run Lengths

Standalone fixtures are available in 4′, 6′ and 8′ nominal lengths. Available in any run length in 2ft increments, starting from 4ft.

Energy + Light

65 UP | 35 DN

100 DOWN
20 UP | 80 DOWN
55 UP | 45 DOWN
A - 19W | 2500 lm
A - 19W | 2550 lm
A - 19W | 2600 lm
A - 19W | 2500 lm
B - 23W | 3050 lm
B - 23W | 3050 lm
B - 23W | 3100 lm
B - 23W | 3000 lm
C - 29W | 3750 lm
C - 29W | 3750 lm
C - 29W | 3750 lm
C - 29W | 3700 lm
D - 38W | 4900 lm
D - 38W | 4800 lm
D - 38W | 4850 lm
D - 38W | 4850 lm
[A] 65 Up | 35 DN
[B] 100 DN
[D] 20 UP | 80 DN
[E] 55 UP | 45 DN

Options

CCT
CEILING TYPE
VOLTAGE
SUSPENSION
[30] 3000 K
[D] Drywall
[M] 120-277 V
[03] ≤ 3ft
[35] 3500 K
[G] Grid
[3] 347 V
[06] ≤ 6ft
[40] 4000 K
[S] Structure
[12] ≤ 12ft
[R] Remote
[25] ≤ 25ft
DRIVER
WIRING + EMERGENCY

SENSORS + CONTROLS
[F1] Non-Dim[A] Alternate wiring for AV, EM or NL[SE1] Canopy Integrated Enlighted Smart Sensor
[F2] 0-10V Dim 3% 120-277V
[B] Battery Pack[RE1] Remote Enlighted Smart Sensor
[F3] 0-10V Dim 3% 347V[C] Chicago Plenum[VN1] Acuity nLight Converter
[E1] eldoLED ECO 0-10V Dim 1%
[H] Emergency Switching
[E2] eldoLED SOLO 0-10V Dim 0.1%
[E3] eldoLED ECO DALI 1%
[E4] eldoLED SOLO DALI Dim 0.1%
[L1] Lutron Hi-Lume 1% EcoSystem (LDE1)

Independent Up | Down Lighting Control

Loop Suspended U|D provides fully dimmable or switchable independent control of the indirect and direct distributions. Ideal for multipurpose rooms and spaces with presentation, projection or video conferencing requirements, the separated circuitry allows simple adjustment of the proportions of up|down light to suit the lighting and energy needs of the space and people in the environment.

Loop UD is available with a native distribution of 55 Up | 45 Dn with a maximum total delivered output of 4200 lumens.

[E] 55 UP | 45 DN
Independent Up | Dn Lighting Control
DISTRIBUTIONENERGYCCT
[B] Independent Up | Dn Control[D] 38 W[30] 3000 K
[35] 3500 K
[40] 4000 K

Mounting + Ceiling Integration

Loop comes with pre-wired and tested drivers that are fully integrated with power junction box, mounting and suspension components. Integrated drivers with ceiling and mounting components are designed for multiple orientations and to accommodate grid, drywall or hard lid ceilings.

Elements can be installed in advance or with fixtures for existing or new construction.  See Ceiling Integration for details.

Top